Specifications |
|
|
Bandwidth |
Fluke 190-204: 200 MHz Fluke 190-202: 200 MHz Fluke 190-104: 100 MHz Fluke 190-102: 100 MHz Fluke 190-062: 60 MHz |
|
Number of Channels |
Fluke 190-204: 200 MHz: 4 channels Fluke 190-202: 200 MHz: 2 channels Fluke 190-104: 100 MHz: 4 channels Fluke 190-102: 100 MHz: 2 channels Fluke 190-062: 60 MHz: 2 channels |
|
Real-time sample rate |
Fluke 190-204: 2.5 GS/s Fluke 190-202: 2.5 GS/s Fluke 190-104: 1.25 GS/s Fluke 190-102: 1.25 GS/s Fluke 190-062: 625 MS/s |
|
Inputs |
4 scope or 2 scope plus DMM input |
|
Independently floating isolated inputs |
Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground |
|
Timebase range |
2 ns - 2 min/div (190-20X, 200 MHz models) 5 ns - 2 min/div (190-10X, 100 MHz models) 10 ns - 2 min/div (190-062, 60 MHz model) |
|
Input sensitivity |
2 mV-100 V/div |
|
Trigger types |
Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle |
|
Trigger Source |
Any scope input channel, or external via DMM input on 190-XX2, 2 channel models |
|
Glitch capture |
8 ns |
|
Scope measurements |
Cursor: 7 Automatic: 30 |
|
Maximum record length |
ScopeRecord mode: 30,000 pts Scope mode: 10,000 pts per input |
|
Persistence |
Digital persistence giving analog oscilloscope-like waveform decay |
|
Waveform Compare |
Waveform reference with automatic Pass/Fail testing |
DMM Specification (2-channel models) |
|
|
Meter inputs (also used as External Trigger Input for the Oscilloscope Mode) |
4 mm banana inputs, fully isolated from scope inputs and from scope ground |
|
Maximum Resolution: |
5000 counts |
|
Measurements: |
Vdc, Vac rms, Vac+dc rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature ºC or ºF (using optional converter) |
|
Memory |
190-X04, 4 Channel Internal Memory: 190-XX2, 2 Channel Internal Memory: |
|
Display |
153 mm full color LCD with fast update rate |
Environmental Specifications |
|
|
Operating Temperature |
0ºC to 40ºC Including Batteries 0ºC to 50ºC Excluding Batteries |
|
Storage Temperature |
-20°C to +60°C |
|
Operating Altitude |
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V |
Safety Specifications |
|
|
Electrical Safety |
1,000V CAT III/600V CAT IV (EN61010-1) |
Mechanical & General Specifications |
|
|
Size |
270 x 190 x 70 mm |
|
Weight |
2.2 kg |
|
Warranty |
3-years on main instrument, 1-year on accessories |
|
Li-Ion Battery |
190-X04, 4 Channel models: BP291 4800 mAh battery up to 7 Hours included standard 190-XX2, 2 Channel models: BP290 2400 mAh battery up to 4 hours included standard. Up to 8 hours using optional BP291 |
Included Accessories |
|
|
Two channel models |
VPS410 Voltage Probe Sets (one red, one blue) |
|
Four channel models |
VPS410 Voltage Probe Sets (one red, one blue, one grey, one green) |
|
Warranty |